Tempstar HVAC Repair & Service in Hayward

Tempstar is an ICP brand, built by the same company as Heil and Comfortmaker, and ICP is owned by Carrier. For a Tempstar owner that means standard parts that are easy to find.

  • Licensed and insured
  • Same-day service
  • 24/7 emergency line

Tempstar furnaces, central air conditioners and heat pumps are straightforward, value-priced equipment, often chosen for budget-focused builds and replacements. In Hayward that can be a Tempstar furnace in the hall closet of a 1960s house or a Tempstar condenser behind a newer townhome. The parts inside are standard and easy to get; the work is in finding which one failed. We are an independent service company, not affiliated with Tempstar, ICP or Carrier.

Part of the ICP family

Tempstar is made by ICP, the company behind Heil and Comfortmaker, and ICP is owned by Carrier. The brands share much of their engineering, so a Tempstar and a Heil furnace of the same type can take the same igniter or control board. That is why Tempstar parts are readily available. The name on the cabinet matters less than the model number on the data plate, which is what we order from.

Tempstar furnaces: read the status light first

Most Tempstar gas furnaces have a status light on the control board behind the blower door, often visible through a small window, and a chart on the door that explains the flash codes. Count the flashes before you turn the furnace off; cutting the power erases the code. The faults we see most:

  • Flame sensor. The burners light, then go out after a few seconds. Cleaning or replacing the sensor fixes it.
  • Pressure switch. The inducer runs but the burners never light. On a high-efficiency furnace a blocked condensate trap or drain hose is a frequent cause; on any furnace, a blocked vent or a weak inducer.
  • Limit switch. The furnace heats, shuts off early and repeats. That usually means poor airflow: a clogged filter, closed vents or a weak blower. Our guide to furnace cycling too frequently goes deeper.
  • Igniter. The inducer runs, the igniter never glows, and the furnace locks out after a few tries.

Outdoor units: the standard ICP wear items

What you noticeLikely causeWhat it usually takes
Fan still, unit hummingWeak or failed capacitorCapacitor test and replacement
Indoor fan runs, outdoor unit silentPitted contactor or a thermostat wiring faultContactor and low-voltage circuit check
Outdoor unit keeps running after the thermostat is offContactor stuck closedSwitch it off at the breaker; contactor replacement
Heat pump coil iced over in winterDefrost control or sensorDefrost cycle test
Short, frequent cyclesThermostat, oversized unit or refrigerant problemTesting first; see short cycling

What a Tempstar tune-up checks

Annual maintenance is what gets the most life out of value equipment. Our yearly visit covers:

  • Furnace: burner flame, igniter and flame sensor, inducer and pressure switch, venting, the condensate trap on high-efficiency models, the visible parts of the heat exchanger and a carbon monoxide check.
  • Air conditioner or heat pump: capacitor measured against its rating, contactor contacts, outdoor coil cleaned, refrigerant performance and, on a heat pump, a defrost test.
  • Both: filter, thermostat and blower.

Each of these wears with every cycle, and finding a worn part on a scheduled visit beats a breakdown call. The full list is on our HVAC maintenance page.

Warranty and parts

Tempstar, like the other ICP brands, offers a longer parts warranty on registered equipment and a shorter base term otherwise; the certificate for your model has the details. The coverage is for parts. Labor is separate unless an extended labor plan was bought with the system. Our repairs carry a warranty, and we use manufacturer-recommended parts.

Repair or replace

A flame sensor, igniter, capacitor, contactor, inducer or control board on a sound system is a repair. A cracked heat exchanger in an older furnace is the clearest case for replacement: it can let combustion gases into the airstream, so the furnace should not be run. Hill homes, which run cooler and windier than the flats, may need more heating capacity than the original furnace had, so a replacement there should be sized for the house, not copied from the old label. See furnace installation.

Hayward homeowners ask

Who makes Tempstar?

ICP, the company that also makes Heil and Comfortmaker. ICP is owned by Carrier, and its brands share much of their equipment and many parts.

My Tempstar furnace lights, then shuts off after a few seconds. Why?

The control cannot confirm the flame, so it closes the gas valve. A dirty flame sensor is the usual cause; cleaning or replacing it fixes most of these calls.

What does the blinking light on my Tempstar furnace mean?

It is a fault code. Count the flashes and match them to the chart on the furnace door before you switch the power off, since cutting the power clears the code.

Are Tempstar parts hard to find?

No. Common parts such as capacitors, contactors, igniters and flame sensors are widely stocked, and specific boards and motors are ordered by model number.

When is an old Tempstar furnace not worth repairing?

When the heat exchanger is cracked, or when a major part fails on an older furnace that has needed repeated repairs. A cracked heat exchanger is a safety problem, and the furnace should not be run.

No heat or no cooling?

Licensed and insured · Same-day service · 24/7 emergency line · Upfront pricing

Call (650) 540-7205